Skip to content

BuiltInFailures.FabricFailures

Public Class

Failures about Fabric.

Inheritance Hierarchy

System.Object
Autodesk.Revit.DB.BuiltInFailures.FabricFailures

Namespace: Autodesk.Revit.DB

Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)

Syntax

public static class FabricFailures

The BuiltInFailures.FabricFailures type exposes the following members.

Properties

Name

Description


Public Property
Static Member

Fabric Bend Diameter is negative.


Public Property
Static Member

The bend profile contains too short of a segment to apply the wire bend diameter. Cannot create a bent fabric sheet for this type.


Public Property
Static Member

The wires of this custom fabric sheet type are longer than the bending sketch. The linear quantities shown in schedules and tags are not accurate.


Public Property
Static Member

Can’t find a host for Fabric Area.


Public Property
Static Member

Can’t find a host for Fabric Area.


Public Property
Static Member

Can’t find a host for Fabric Sheet.


Public Property
Static Member

Can’t find a host for Fabric Sheet.


Public Property
Static Member

Cover offset is greater than host thickness.


Public Property
Static Member

Cover offset is greater than host thickness - support for transient Single Fabric Sheet in editor.


Public Property
Static Member

Fabric Area can be placed only in Structural Floors and straight Structural Walls.


Public Property
Static Member

Fabric Area Sheet lap splice is incorrect. Can’t create Fabric Area.


Public Property
Static Member

Fabric Area Sheet Alignment is incorrect. Can’t create Fabric Area.


Public Property
Static Member

Fabric Sheet can be placed only in Structural Floors and straight Structural Walls.


Public Property
Static Member

The lap splice in the major direction is greater than the half of the overall length.


Public Property
Static Member

At least one of the overhangs in the major direction is lower than radius of the wire in the minor direction.


Public Property
Static Member

The spacing in the major direction is lower than diameter of the wire in the minor direction.


Public Property
Static Member

The lap splice in the minor direction is greater than the half of the overall width.


Public Property
Static Member

At least one of the overhangs in the minor direction is lower than radius of the wire in the major direction.


Public Property
Static Member

The spacing in the minor direction is lower than diameter of the wire in the major direction.


Public Property
Static Member

Wire elements do not support surface patterns. The surface pattern associated with this material will not be displayed on the indicated Fabric Sheet Type.


Public Property
Static Member

Material does not have a density defined. The weight of the Fabric Sheet cannot be computed.


Public Property
Static Member

Fabric Wire Diameter is too large.


Public Property
Static Member

Wrong Start Overhang of the Fabric Sheet Type.


Public Property
Static Member

The Layout Pattern cannot accommodate the current data. Try decreasing the Number of Wires/Spacing.


Public Property
Static Member

Wrong Number of Wires of the Fabric Sheet Type.


Public Property
Static Member

Wrong Overall Length/Width of the Fabric Sheet Type.


Public Property
Static Member

Wrong Spacing of the Fabric Sheet Type.


Public Property
Static Member

Wrong Start Overhang of the Fabric Sheet Type.