FabricationConnectorInfo.DoubleWallConnectorId

Public Property

Fabrication double wall connector Id.

Namespace: Autodesk.Revit.DB

Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)

Syntax

public int DoubleWallConnectorId { get; set; }

Property Value

Int32

Exceptions

Exception

Condition


ArgumentException

When setting this property: doubleWallConnectorId is invalid based on the shape and domain.


InvalidOperationException

No double wall connector available. -or- When setting this property: the connector cannot be modified on an owned fabrication part. -or- When setting this property: the connector is already connected. -or- When setting this property: the fabrication part is connected to more than one item.


Remarks

A reference to the fabrication configuration connectors. Setting the connector value will also set the connector lock. A value of 0 indicates no connector.