BuiltInFailures.PipingFailures
Failures about Pipes.
Inheritance Hierarchy
System.Object
Autodesk.Revit.DB.BuiltInFailures.PipingFailures
Namespace: Autodesk.Revit.DB
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public static class PipingFailuresThe BuiltInFailures.PipingFailures type exposes the following members.
Properties
Name
Description
Public Property
Static Member
CannotCreateGeometryForPipe
Cannot create geometry for flex pipe. The flex pipe is intersecting itself or the start and end are too close together.
Public Property
Static Member
CircularLoopInPipeSizing
Circular loop detected during pipe sizing. The loop may be avoided by modifying segment settings in the pipe routing preference.
Public Property
Static Member
DuctPipeModified
The duct/pipe has been modified to be in the opposite direction causing the connections to be invalid.
Public Property
Static Member
DuctPipeSizeMismatch
The duct/pipe size is invalid for the service definition
Public Property
Static Member
FabFittingFailed
The Fabrication Fitting was invalid
Public Property
Static Member
InvalidPipeSize
Pipe Size Table “[File Name]” is missing or invalid.
Public Property
Static Member
MaxPipeSizeReached
Maximum pipe size diameter reached during sizing
Public Property
Static Member
PartNotFoundDueToNoPipeConnectedError
“In order to find a matching part, the fitting has to be connected to a pipe.”
Public Property
Static Member
PartNotFoundDueToNoPipeConnectedWarning
“In order to find a matching part, the fitting has to be connected to a pipe.”
Public Property
Static Member
PartNotFoundInRoutingPreferenceError
“%1s is not found. Please review the routing preference of %2s.”
Public Property
Static Member
PartNotFoundInRoutingPreferenceWarning
“%1s is not found. Please review the routing preference of %2s.”