PanelScheduleView.SwitchPhases
Public Class
ArgumentException
ArgumentOutOfRangeException
InvalidOperationException
Switches the circuit phases at the slot.
Namespace: Autodesk.Revit.DB.Electrical
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public void SwitchPhases( int nRow, int nCol)
Parameters
nRowInt32
Row Number.
nColInt32
Column Number.
Exceptions
Exception
Condition
ArgumentException
The circuit at given cell (nRow, nCol) is not one or two poles circuit.
ArgumentOutOfRangeException
The given row number nRow is invalid in Body. -or- The given column number nCol is invalid in Body. -or- There is no circuit at given cell (nRow, nCol).
InvalidOperationException
This is not a switchboard panel schedule.
Remarks
Only one or two poles circuit on switchboard panel schedule can switch phases.