MechanicalUtils.BreakCurve
Public Class
ArgumentException
ArgumentNullException
Breaks the duct curve into two parts at the given position.
Namespace: Autodesk.Revit.DB.Mechanical
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public static ElementId BreakCurve( Document document, ElementId ductId, XYZ ptBreak)
Parameters
document Document
The document.
ductId ElementId
The element id of the duct curve to break.
ptBreak XYZ
The break point on the duct curve.
Return Value
ElementId
The new duct curve element id if successful otherwise if a failure occurred an invalidElementId is returned.
Exceptions
Exception
Condition
ArgumentException
“The element is neither a duct nor a duct placeholder.” -or- “The given point is not on the duct curve.”
ArgumentNullException
A non-optional argument was null
Remarks
This method is not applicable for breaking the flex duct.