Skip to content

AnalyticalTransformerData.SecondaryDistributionSystem

Public Property

The secondary distribution system of the analytical transformer.

Namespace: Autodesk.Revit.DB.Electrical

Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)

Syntax

public ElementId SecondaryDistributionSystem { get; set; }

Property Value

ElementId

Exceptions

Exception

Condition


ArgumentException

When setting this property: The id is neither a distribution system id nor InvalidElementId. -or- When setting this property: The secondary distribution system id can’t be set to the analytical transformer.


ArgumentNullException

When setting this property: A non-optional argument was null


Remarks

In the case of a transformer, it’s crucial that the number of phases in the secondary distribution system matches that of the primary distribution system. If the number of phases in the secondary system is set to be different from that of the primary distribution system, it will result in a ‘SecondaryNumOfPhasesNotEqualWithPrimary’ error. If you anticipate this discrepancy, you can avoid the error by first setting the secondary distribution system to InvalidElementId, and then setting the primary distribution system.