BuiltInFailures.RebarSystemFailures
Failures related to rebar systems.
Inheritance Hierarchy
System.Object
Autodesk.Revit.DB.BuiltInFailures.RebarSystemFailures
Namespace: Autodesk.Revit.DB
Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)
Syntax
public static class RebarSystemFailuresThe BuiltInFailures.RebarSystemFailures type exposes the following members.
Properties
Name
Description
Public Property
Static Member
AreaReinforcementOutSideOfHost
Area Reinforcement is sketched completely outside of its host.
Public Property
Static Member
AreaReinforcementRegenFail
Can’t regenerate Area Reinforcement.
Public Property
Static Member
AreaReinforcementsCollision
Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision.
Public Property
Static Member
AreaReinforcementWrongHost
Area Reinforcement can be placed only in Structural Floors and straight Structural Walls.
Public Property
Static Member
BarsTooCloseNumber
Bars are too close together. Decrease the Number Of Lines parameter.
Public Property
Static Member
BarsTooCloseSpacing
Bars are too close together. Increase the Maximum Spacing parameter.
Public Property
Static Member
BarsTooSparseSpacing
Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter.
Public Property
Static Member
CannotPlaceAreaReinforcement
Can’t find a host for Area Reinforcement.
Public Property
Static Member
CannotPlaceAreaReinforcementWarn
Can’t find a host for Area Reinforcement.
Public Property
Static Member
CannotPlaceAreaReininforcement
Can’t find a host for Area Reinforcement.
Public Property
Static Member
CannotPlaceAreaReininforcementWarn
Can’t find a host for Area Reinforcement.
Public Property
Static Member
CannotPlacePathReinforcement
Can’t find a host for Path Reinforcement.
Public Property
Static Member
CannotPlacePathReinforcementWarn
Can’t find a host for Path Reinforcement.
Public Property
Static Member
CannotPlacePathReininforcement
Can’t find a host for Path Reinforcement.
Public Property
Static Member
CannotPlacePathReininforcementWarn
Can’t find a host for Path Reinforcement.
Public Property
Static Member
CannotUseAreaReinforcementHookTypeStyle
At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
Public Property
Static Member
CannotUsePathReinforcementHookTypeStyle
At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
Public Property
Static Member
DPartReinfDeletedEditDivision
Edits to the model will cause some Reinforcement hosted on Parts to be deleted.
Public Property
Static Member
DPartReinforcementDeleted
Reinforcement hosted on highlighted Parts will be deleted.
Public Property
Static Member
HostFlagAreaOff
Public Property
Static Member
HostFlagAreaOn
The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off.
Public Property
Static Member
HostFlagPathOff
Public Property
Static Member
HostFlagPathOn
Public Property
Static Member
InvalidLapSpliceInAreaReinforcement
The instance major/minor lap lengths must be smaller than 1/2 of the overall length from the type in major and minor directions, respectively. The default values set for this parameters did not respect this criteria so they were automatically reset to the type values.
Public Property
Static Member
LessThanTwoBars
Each reinforcement direction requires at least 2 bars. Please increase the number of bars.
Public Property
Static Member
PathReinforcementWrongHost
Path Reinforcement can be placed only in Structural Floors and straight Structural Walls.
Public Property
Static Member
RebarSystemOffset
Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate.
Public Property
Static Member
ThinHostFloor
Rebar Cover Top and Bottom are too large for host.
Public Property
Static Member
ThinHostFloorError
Rebar Cover Top and Bottom are too large for host.
Public Property
Static Member
ThinHostWall
Rebar Cover Interior and Exterior are too large for host.
Public Property
Static Member
ThinHostWallError
Rebar Cover Interior and Exterior are too large for host.